Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Ciênc. rural ; 46(4): 681-685, Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-775138

ABSTRACT

ABSTRACT: The brainstem auditory evoked potential (BAEP) evaluates the integrity of the auditory pathways to the brainstem. The aim of this study was to evoke BAEPs in 21 clinically normal horses. The animals were sedated with detomidine hydrochloride (0.013mg.kg-1 BW). Earphones were inserted and rarefaction clicks at 90 dB and noise masking at 40 dB were used. After performing the test, the latencies of waves (I, II, III, IV, and V) and interpeaks(I-III, III-V, and I-V) were identified. The mean latencies of the waves were as follows: wave I, 2.4 ms; wave II, 2.24 ms; wave III, 3.61ms; wave IV, 4.61ms; and wave V, 5.49ms. The mean latencies of the interpeaks were as follows: I-III, 1.37ms; III-V, 1.88ms; and I-V, 3.26ms. This is the first study using BAEPs in horses in Brazil, and the observed latencies will be used as normative data for the interpretation of tests performed on horses with changes related to auditory system or neurologic abnormalities.


RESUMO: O Potencial Evocado Auditivo de Tronco Encefálico (BAEP-Brainstem Auditory Evoked Potential) avalia a integridade das vias auditivas até o tronco encefálico. O objetivo da pesquisa foi padronizar o uso do BAEP em 21 equinos, sem aparente anormalidade auditiva. Os animais foram sedados com cloridrato de detomidina (0,013mg.kg-1 de PV). Foram utilizados fones de inserção,cliques de rarefação a 90 dB e um ruído de mascaramento de 40 dB. Foram identificadas as latências das ondas I, II, III, IV e V e dos interpicos I-III, III-V e I-V. As médias das latências das ondas foram: onda I 2,24ms; onda II 2,74ms; onda III 3,61ms; onda IV 4,61ms; e onda V 5,49ms. As médias das latências dos interpicos foram: I-III 1,37ms; III-V 1,88ms; e I-V 3,26ms. Este é o primeiro estudo utilizando o BAEP em equinos no Brasil e as latências observadas serão utilizadas como dados normativos para interpretação de exames de cavalos com anormalidades auditivas ou neurológicas.

2.
Ciênc. rural ; 44(5): 891-896, maio 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-707034

ABSTRACT

O potencial evocado auditivo de tronco encefálico (Brainstem Auditory Evoked Potential - BAEP) avalia a atividade elétrica do sistema auditivo, desde a cóclea até o tronco encefálico, permitindo diagnóstico de surdez em cães. Como alguns animais não permitem a obtenção do BAEP sem contenção química, o objetivo deste trabalho foi analisar a influência da sedação com morfina e acepromazinano BAEP de 16 cães com audição normal. Os potenciais foram obtidos antes e durante a sedação com administração intramuscular de morfina (0,5mgkg-1) e acepromazina (0,05mgkg-1). O protocolo de sedação utilizado permitiu contenção efetiva e segurança dos animais. A sedação causou prolongamento nas latências das ondas II, III e intervalos I-III e I-V, mas não dificultou as suas identificações. O uso deste protocolo de sedação não interferiu com a interpretação do potencial evocado e pode ser útil em cães. Pelo que se pode observar na literatura compilada, este é o primeiro estudo avaliando a influência da sedação no BAEP em cães no Brasil.


Brainstem auditory evoked potential (BAEP) reflects the electrical activity along the auditory pathway, from the cochlea to the brainstem, and contributes for the diagnosis of deafness in dogs. BAEP recording may require chemical restraint in some cases, so this study was designed to analyze the impact of sedation with morphine and acepromazine on the BAEP recordings of 16 dogs with normal hearing. BAEPs were recorded before and during sedation with a combination of morphine (0.5mgkg-1) and acepromazine (0.05mgkg-1) given intramuscularly. The protocol employed allowed safe and effective animal restraint. Sedation increased the latency of waves II and III and intervals I-III and I-V but did not interfere with wave identification. and showed to be safe in the dogs tested. Based on the current literature this is the first study which assessed the impact of sedation on BAEPs in dogs in Brazil.

3.
Botucatu; s.n; 2013. 87 p. ilus, tab.
Thesis in Portuguese | LILACS | ID: lil-751572

ABSTRACT

Estudos para desenvolver técnicas mais aperfeiçoadas na abordagem da dor merecem atenção. As nanopartículas são carreadores de fármacos, que podem aumentar sua eficácia terapêutica e diminuir os efeitos adversos. Ao considerar a possível excitação causada pelo uso de opioides por via IV, objetivou-se estudar opções alternativas a esta via para administrar metadona em equinos. seis éguas, de 2 a 4 anos, com peso médio de 354 ± 34 kg receberam com intervalo de sete dias e de forma aleatória 0,5 mg/kg de cloridrato de metadona O, IM e IV e nanopartículas lipídicas sólidas O. O avaliador não ciente do tratamento registrou a pressão arterial sistólica (PAS), a distancia do lábio inferior ao chão, as frequências cardíaca e respiratória, a motilidade intestinal e os limiares nociceptivos térmico, mecânico e elétrico durante 4 horas. Colheu-se sangue durante 6 horas para posterior análise da concentração plasmática de metadona por cromatografia de alta eficiência (CLAE). Avaliaram-se os perfis plasmáticos de metadona por abordagem não compartimental e compartimental. Analisou-se os dados paramétricos por modelos de medidas repetidas para avaliar diferenças entre os tratamentos e momentos. Usou-se o teste de Tukey para ajustar os valores-P resultantes das comparações múltiplas. Para dados não paramétricos, utilizou-se o teste Wilcoxon para comparar os tratamentos em cada momento e o de Bonferroni para ajustar o valor-P resultante das comparações múltiplas (p < 0,05). Em relação ao valor basal, nos animais tratados por via IV, a PAS aumentou por 80 minutos, os movimentos intestinais diminuíram entre 45 e 80 minutos e o limiar nociceptivo mecânico aumentou por 45 minutos...


Studies for the development of improved techniques for pain management deserve attention. Nanoparticles are carriers of drugs used to increase therapeutic efficacy and decrease adverse effects. Excitement is usually observed when opioids are administered intravenously. This study aimed to investigate new options, besides the intravenous route, for methadone administration in horses. The antinociceptive effect, physiologic parameters and pharmacokinetics (PK) were evaluated. Six mares (354 ± 34 kg; 2 - 4 years) received 0.5 mg/kg of oral, intramuscular and intravenous methadone or orally methadone nanoparticles formulation prepared in-house, at one week interval. A blinded observer registered non invasive systolic arterial blood pressure (SAP), heart and respiratory rates, distance from the floor to animal’s muzzle, intestinal motility, and mechanical, thermal and electrical nociceptive thresholds for four hours. Blood samples were collected for up to six hours for measurement of plasma methadone concentration. Methadone PK was evaluated by non-compartmental and compartmental modeling. Two way ANOVA followed by Tukey or Wilcoxon test was used to compare differences among groups, followed by Bonferroni correction for multiple comparisons (P < 0.05). Compared to basal values, IV methadone increase SAP for 80 minutes, reduced intestinal motility between 45 and 80 minutes and increased mechanical threshold for 45 minutes. Thermal nociceptive thresholds increased for 60 and 80 minutes after IM and IV methadone and electrical nociceptive thresholds increased for 140 minute after IM methadone and from 45 to 240 minutes after IV methadone. After IV methadone, elimination was rapid (0.92 ± 0.32 L/h/kg for IV), half life was short (0.63 ± 0.11 h for IV) and mean retention time was 0.97 ± .0.17 h...


Subject(s)
Animals , Analgesics, Opioid , Horses , Methadone/pharmacokinetics , Methadone/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL